APC C Metered Rack PDU - Power distribution unit (rack-mountable) - AC 208 V - 10 kW - 3-phase - Ethernet 10/100, RS-232 - output connectors: 42 - 0U - Canada, United States - black - for P/N: SMX1000C, S
Frontpage
Components
Component Acc.
APC C Metered Rack PDU - Power distribution unit (rack-mountable) - AC 208 V - 10 kW - 3-phase - Ethernet 10/100, RS-232 - output connectors: 42 - 0U - Canada, United States - black - for P/N: SMX1000C, S
|
APC C Metered Rack PDU - Power distribution unit (rack-mountable) - AC 208 V - 10 kW - 3-phase - Ethernet 10/100, RS-232 - output connectors: 42 - 0U - Canada, United States - black - for P/N: SMX1000C, S
LEASING
( ex. sales tax)
Setup fee 0,-, invoice charge 0,-/month, minimum order 0,-. Freight and salestax (if applicable) are additional. On approved credit. Lease is selected as a payment option in the checkout.
|
Description
Specifications
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
PDU types | Metered |
Rack capacity | 0U |
Mounting | Vertical |
Product colour | Black |
AC outlets quantity | 42 AC outlet(s) |
Input connection type | CS8365 |
Output connections | 36 x IEC 320 C13
6 x IEC 320 C19 |
Cable length | 1.83 m |
Nominal input voltage | 208 V |
AC input frequency | 50 - 60 Hz |
Nominal output voltage | 208 V |
Load capacity | 10000 VA |
Maximum input current per phase | 35 A |
Maximum total current draw per phase | 35 A |
Power protection features | Overload |
Compliance certificates | RoHS |
Certification | cUL, EN 55022, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC, ICES-003, UL, VCCI |
Operating temperature (T-T) | 0 - 55 °C |
Storage temperature (T-T) | -25 - 65 °C |
Operating relative humidity (H-H) | 5 - 95% |
Storage relative humidity (H-H) | 5 - 95% |
Operating altitude | 0 - 3000 m |
Non-operating altitude | 0 - 15000 m |
Width | 56 mm |
Depth | 51 mm |
Height | 1829 mm |
Weight | 8.52 kg |
Package weight | 11.4 kg |
Package width | 170 mm |
Package depth | 112 mm |
Package height | 2050 mm |
Total carbon footprint (kg of CO2e) | 51678.25 |
Please note that although care has been taken in the degree of relevancy, pictures are for
display purposes only, and product appearance may differ from what you see. If there are any
discrepancies between the product headline, description and picture, the correct information
will be in the product headline (i.e. computer systems may not come with monitors even if
pictured that way). If anything is unclear, please email support before placing your order.